Schneider Electric TeSys F kontaktor - 3P(3 NO) - AC-3 - <= 440 V 330 A - bez kalema;LC1F330

Schneider Electric TeSys F kontaktor - 3P(3 NO) - AC-3 - <= 440 V 330 A - bez kalema;LC1F330

TeSys F contactor-3P(3 NO)-AC-3 <= 440V 330A with coil LX1/LX9 -24…1000V AC 40/400Hz, LX4 -24...460V DC, LXE -100...250V AC 50/60Hz or 100…380V...

Brand: Schneider Electric
Product Code: LC1F330
Availability: Check availability
VAT-exclusive price: 152.374,00
VAT-inclusive price: 182.848,80

TeSys F contactor-3P(3 NO)-AC-3 <= 440V 330A with coil LX1/LX9 -24…1000V AC 40/400Hz, LX4 -24...460V DC, LXE -100...250V AC 50/60Hz or 100…380V DC


Main
range
TeSys
 
product name
TeSys F
 
product or component type
Contactor
 
device short name
LC1F
 
contactor application
Motor control
Resistive load
 
utilisation category
AC-4
AC-3
AC-1
 
poles description
3P
 
power pole contact composition
3 NO
 
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz
<= 460 V DC
 
[Ie] rated operational current
400 A (at <40 °C) at <= 440 V AC AC-1
330 A (at <55 °C) at <= 440 V AC AC-3
 
motor power kW
160 kW at 1000 V AC 50/60 Hz (AC-3)
160 kW at 380...400 V AC 50/60 Hz (AC-3)
180 kW at 415 V AC 50/60 Hz (AC-3)
200 kW at 440 V AC 50/60 Hz (AC-3)
200 kW at 500 V AC 50/60 Hz (AC-3)
100 kW at 220...240 V AC 50/60 Hz (AC-3)
220 kW at 660...690 V AC 50/60 Hz (AC-3)
59 kW at 400 V AC 50/60 Hz (AC-4)
 
Complementary
[Uc] control circuit voltage
24...1000 V AC 40...400 Hz with LX1/LX9 coil
24...460 V DC with LX4 coil
100...250 V AC 50/60 Hz with LXE coil
100...380 V DC with LXE coil
 
[Uimp] rated impulse withstand voltage
8 kV
 
overvoltage category
III
 
[Ith] conventional free air thermal current
400 A (at 40 °C)
 
Irms rated making capacity
3300 A AC conforming to IEC 60947-4-1
 
rated breaking capacity
2640 A conforming to IEC 60947-4-1
 
[Icw] rated short-time withstand current
2650 A 40 °C - 10 s
1800 A 40 °C - 30 s
1300 A 40 °C - 1 min
900 A 40 °C - 3 min
750 A 40 °C - 10 min
 
associated fuse rating
400 A aM at <= 440 V
500 A gG at <= 440 V
 
average impedance
0.28 mOhm - Ith 400 A 50 Hz
 
[Ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
 
power dissipation per pole
44 W AC-1
31 W AC-3
 
control circuit voltage limits
Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
Drop-out: 0.35...0.55 Uc AC 40...400 Hz with LX1/LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.15...0.2 Uc DC with LX4 coil
Operational: 85...275 V AC 50/60 Hz with LXE coil
Drop-out: 0...60 V AC 50/60 Hz with LXE coil
Operational: 85...418 V DC with LXE coil
Drop-out: 0...45 V DC with LXE coil
 
heat dissipation
8 W
2.2…5.5 W
 
operating time
40...65 ms closing for with LX1/LX9 coil
100...170 ms opening for with LX1/LX9 coil
40...50 ms closing for with LX4 coil
40...65 ms opening for with LX4 coil
40...80 ms closing for with LXE coil
6...54 ms opening for with LXE coil
 
mounting support
Plate
 
standards
IEC 60947-4-1
JIS C8201-4-1
EN 60947-1
IEC 60947-1
EN 60947-4-1
 
product certifications
ABS
CSA
UL
RMRoS
DNV
CB
BV
LROS (Lloyds register of shipping)
RINA
 
connections - terminals
Power circuit: lugs-ring terminals 1 cable(s) 240 mm²
Power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
 
tightening torque
Power circuit: 35 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m
 
mechanical durability
10 Mcycles
 
inrush power in VA
600…700 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
655…803 VA (at 20 °C)with LX4 coil
300…350 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
300…310 VA (at 20 °C)with LXE coil
 
hold-in power consumption in VA
8…10 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
3.68…4.53 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil
 
maximum operating rate
2400 cyc/h 55 °C
 
compatibility code
LC1F
 
Environment
IP degree of protection
IP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
 
protective treatment
TH
 
ambient air temperature for operation
-5…55 °C
 
ambient air temperature for storage
-60…80 °C
 
permissible ambient air temperature around the device
-40…70 °C
 
  • TeSys F LC1F330

    TeSys F LC1F330



Similar products:


Schneider Electric TeSys F kontaktor - 3P(3 NO) - AC-3 - <= 440 V 115 A - bez kalema; LC1F115

TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 115A with coil LX9 - 24...600V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100…380V DC
-
Need to order

(Out of stock)

 
 
66.608,00

Schneider Electric TeSys F kontaktor - 3P(3 NO) - AC-3 - <= 440 V 150 A - bez kalema; LC1F150

TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 150A with coil LX9 - 24...600V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100…380V DC
-
Need to order

(Out of stock)

 
 
75.752,00

Schneider Electric TeSys F kontaktor - 3P(3 NO) - AC-3 - <= 440 V 185 A - bez kalema; LC1F185

TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 185A with coil LX9 - 24...600V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100…380V DC
-
Need to order

(Out of stock)

 
 
82.941,00

Schneider Electric TeSys F kontaktor - 3P(3 NO) - AC-3 - <= 440 V 225 A - bez kalema; LC1F225

TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 225A with coil LX9 - 24...600V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100…380V DC
-
Need to order

(Out of stock)

 
 
111.969,00

Schneider Electric TeSys F kontaktor - 3P (3 NO) - AC-3 - <= 440 V 330 A - kalem 220 V AC;LC1F330M7

TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC
-
Need to order

(Out of stock)

 
 
172.116,00

Schneider Electric TeSys F kontaktor - 3P(3 NO) - AC-3 - <= 440 V 800 A - bez kalema;LC1F800

TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 800 A with coil LX1/ LX9 - 110…400V AC 40/400Hz, LX4 - 110...400V DC, LXE - 100...250V AC 50/60Hz
-
Need to order

(Out of stock)

 
 
696.566,00

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products